Back to Blog
online case submission dental labdigital case submissiondental lab online portalupload dental scan to lab

How to Submit a Dental Lab Case Online: Step-by-Step

Nov 6, 2026

How to Submit a Dental Lab Case Online: Step-by-Step

Online case submission replaces the courier run for most of the paperwork and data in a restorative case. The prescription, the scans, and the shade reference go to the lab through a portal, and the practice gets a case reference to track everything against.

This guide explains how to submit a dental lab case online, from account setup to the confirmation step. It uses a single zirconia crown as the worked example. Monde Dental Lab's site lets practices submit and ship cases, register accounts, and check pricing online, through separate Send A Case and Ship A Case pages.

What digital case submission covers at a dental lab

Digital case submission handles the information side of a case. Three things travel through the portal: the prescription details, the scan files, and the shade reference.

The prescription is the written instruction set: restoration type, tooth numbers, material, shade, due date, and special instructions. Scan files are the digital impressions exported from the practice's intraoral scanner. The shade reference is the shade guide named on the prescription, plus a photo taken alongside the guide.

Some items still need a courier. Physical impressions, stone models, and any bite records not captured digitally have to be shipped, because a portal cannot carry them.

A practice that scans everything, including the bite, can often send a case with no parcel at all. A practice that takes conventional impressions uses the portal for the prescription and ships the physical items separately.

This does not turn a conventional workflow into a digital one. If the practice does not own an intraoral scanner, online submission covers the prescription and shade photo only, and the impression still ships.

Practices still choosing a lab for zirconia work can read what to look for in a zirconia crown lab before opening an account.

Set up the practice account on the online lab portal

Account setup happens once. After that, every case starts from a saved practice profile instead of a blank form.

Register the practice and its users

Registration on the dental lab online portal asks for three groups of details:

  • Practice details: the practice name, address, and a main contact.
  • Billing details: the information the lab needs to invoice the practice.
  • Shipping details: the address for returned restorations, and the address any parcels come from.

Each doctor or staff member who submits cases gets a separate login. Shared logins look convenient, but they blur who submitted which case, and they leave a former employee's access in place after they have left the practice. With individual logins, each case is tied to the person who sent it, and the practice manager can retire one user without affecting the rest.

The account also gives the practice access to pricing online, so the fee for a restoration can be checked before the case is sent rather than after.

Set default preferences

Where the portal offers default preferences, the practice sets them at registration so each case form opens with the right values. Two matter most.

The first is tooth numbering. Practices in the US use the Universal system. Practices in France and Germany use FDI two-digit notation, as described on Wikipedia. A wrong numbering system is a quiet source of errors, because tooth #14 in Universal is tooth 26 in FDI, and a lab reading the wrong system would be working on a different tooth than the one the dentist prescribed.

The second is the shade guide. A practice that works from VITA Classical (A1 to D4) sets that as the default. A practice using VITA 3D-Master sets that one.

One more habit belongs in the account setup. Where the portal allows it, the practice should identify patients by case reference instead of full name. That limits the personal data stored with each case. In the US, HIPAA governs how patient information is handled. In France and Germany, the GDPR applies. A case reference such as CASE123, matched to the patient in the practice's own records, serves the lab just as well as a name.

Prepare scan files in a format the lab accepts

The most common cause of a delayed case is a file the lab cannot open. Choosing the right export format before upload prevents it.

Choose a file format: STL, PLY, OBJ, and DICOM

Four formats come up in digital dentistry, and they do different jobs:

  • STL is the most widely accepted exchange format. It carries surface geometry only, with no color.
  • PLY can carry color information along with geometry.
  • OBJ can also carry color, usually as a texture file alongside the model.
  • DICOM holds cone-beam CT (CBCT) volumes. These are separate from intraoral surface scans and are handled separately.

For a single crown, STL is usually enough, because the lab designs the restoration from geometry and takes the shade from the prescription and the reference photo. PLY or OBJ adds value when the scan's color data helps the technician see tissue or a stained preparation.

DICOM does not replace a surface scan. A CBCT volume shows bone and anatomy but does not capture the preparation margin the way an intraoral scan does.

Most scanners save in their own project format first. That native file often cannot be opened outside the scanner's software, so the practice exports a standard format before upload. The accepted formats and any size limits are listed on the live Send A Case page, and the practice should check them there before exporting.

Assemble the scan set for one restorative case

A complete scan set for one restorative case has three parts:

  1. The preparation scan. It shows the prepared tooth, with a clearly captured margin.
  2. The opposing arch. The full arch opposite the preparation, so the technician can design the occlusion.
  3. The bite registration. It shows how the upper and lower arches meet.

For the zirconia crown on tooth #14, that means an upper preparation scan, a full lower arch, and a bite registration, each saved as STL.

File names make the set easy to read. Naming each file by case, arch, and scan type works well, for example CASE123_upper_prep.stl, CASE123_lower_opposing.stl, and CASE123_bite.stl. The lab can then see at a glance which file is which, even if the case form is not open.

Submit a dental lab case in the portal

With the account active and the files exported, submission takes a few minutes. Every step is something the practice does, in this order.

Enter the prescription details

The case form follows the order of a written prescription:

  1. Select the restoration type.
  2. Enter the tooth number in the numbering system the practice uses.
  3. Choose the material.
  4. Choose the shade.
  5. Set the due date.
  6. Add any special instructions.

In the worked example, the restoration type is a single crown and the material is zirconia. The tooth is #14 in Universal numbering, or 26 in FDI. A practice in France or Germany enters 26, and a US practice enters 14.

Shade goes on the prescription by naming the guide and the shade, such as A2 from VITA Classical or a code from VITA 3D-Master. A reference photo taken alongside the physical shade guide backs that up. The photo shows the lab what the dentist saw, which a shade code alone cannot.

The due date is the day the practice needs the restoration, which is not always the day of the patient's seating appointment. Special instructions cover anything the form fields do not, such as a tight contact with the neighboring tooth or a preference for a particular occlusal scheme.

Upload dental scan files to the lab

To upload a dental scan to the lab, the practice attaches each exported file to the case. Preparation scan, opposing arch, and bite registration each go on as their own file.

The practice then checks the case before submitting. The file list should show every file, and the file names should match the case reference. The tooth number, material, and shade on the form should match the written prescription. Fixing a wrong tooth number takes seconds before submission. After the lab has started the case, the same mistake costs a remake.

Submitting sends the prescription and files together, and the case reference is generated. The practice keeps that reference for every follow-up with the lab.

Once the account is registered and the scan set is exported, the practice can open the Send A Case page and submit its first digital case.

Fix common upload problems

Most upload problems have one of four causes. Working through them in order is quicker than guessing.

Files that will not upload or open

Unsupported format. A scanner-native project file will fail, or it will upload but not open at the lab. The fix is to re-export the scan as STL, PLY, or OBJ and attach the new file.

File size. Large scans, especially color files, can exceed the portal's size limit. Where limits apply, compressing the files into a single folder often brings them under the cap. Whether compressed folders are accepted is listed on the Send A Case page, so the practice checks there before zipping.

Missing margin. A preparation scan that does not fully capture the margin cannot be designed from reliably. Uploading it does not help, because the gap is in the data and not in the file. The fix is a re-scan of the affected area, with the margin clearly visible all the way round.

Bite that does not match the arches. If the bite registration does not line up with the preparation and opposing scans, the technician cannot trust the occlusion. The practice re-scans the bite, making sure the patient closes in their normal position.

Re-exporting and re-scanning solve nearly every case. If a file still fails after that, the practice can reach the lab through the Contact page and quote the case reference.

What happens after the case is submitted

After submission, the lab works from what the practice sent. Turnaround depends on the restoration, the material, and the due date set on the prescription. A complete case moves faster than one the lab must query, because every question sent back to the practice stops the clock.

Confirm the case reference and file list

Right after submitting, the practice confirms two things. The case should appear on record under its case reference. Every file attached, including the bite registration, should appear in the file list.

If a file is missing from the list, the practice attaches it then, not after the lab asks. A scan that never arrived looks the same as a scan that was never taken.

The case reference is the one identifier that matters from here. It goes into every message to the lab, and it goes onto any physical item that ships.

Pair digital files with physical items

Some cases need both channels. Impressions, stone models, and wax bites that were not captured digitally still ship to the lab. A practice sending a conventional impression with a digital prescription is a common pairing.

The practice can ship impressions and models through Ship A Case, which covers the physical side of the same workflow.

The digital submission and the parcel need to match up. The practice writes the same case reference on the parcel, on the packing slip, and on any item inside, so the lab can pair the box with the digital case on arrival. A parcel without a reference has to be identified by hand, and that is where cases stall.

Frequently asked questions

Can I submit a dental lab case online without shipping anything?

Yes, if the practice captures the preparation, the opposing arch, and the bite with an intraoral scanner. The prescription, scan files, and shade reference then all go through the portal. Practices that take conventional impressions or use wax bites still ship those items.

Which scan file format should I use for a single crown?

STL is the safest choice because it is the most widely accepted exchange format. It carries geometry only, which is enough for most single-crown designs when the shade is on the prescription. PLY or OBJ is an option when color data is useful.

Can I upload a CBCT scan instead of an intraoral scan?

No. A CBCT volume is saved as DICOM and is handled separately from surface scans. It does not capture the preparation margin the way an intraoral scan does, so a restorative case still needs the preparation scan, opposing arch, and bite.

Does each dentist in the practice need their own login?

Yes, each doctor or staff member who submits cases should have a separate login. That ties each case to the person who submitted it. It also lets the practice remove one user's access without disturbing the others.

What should I do if my scan will not upload?

First check the format and re-export as STL, PLY, or OBJ if the file is a scanner-native project file. Then compress the files if size limits apply. If the file still fails, contact the lab through the Contact page and give the case reference.

Start With a Case Today

Experience the Monde process directly — it's the clearest way to understand the laboratory.

USA 872.216.0319